Search
"Dynamic needle-tip positioning is efficacious for peripheral venous catheterization in children. It would be better to include dynamic needle-tip positioning for the ultrasound-guided short-axis out-of-plane approach" Takeshita et al (2023).

Abstract:

Abstract:

Objectives: To compare the efficacy of the ultrasound-guided approach with and without dynamic needle-tip positioning and the palpation technique regarding success for peripheral venous catheterization in children.

Design: A systematic review with network meta-analysis.

Setting: Databases of MEDLINE (via PubMed) and Cochrane Central Register of Controlled Trials.

Participants: Patients (<18 years) undergoing peripheral venous catheter insertion.

Interventions: Randomized clinical trials were included to compare the following techniques: the ultrasound-guided short-axis out-of-plane approach with dynamic needle-tip positioning, the approach without dynamic needle-tip positioning, and the palpation technique.

Measurements and main results: The outcomes were first-attempt and overall success rates. Eight studies were included in the qualitative analyses. According to the estimate of network comparison, dynamic needle-tip positioning was associated with higher first-attempt (risk ratio [RR] 1.67; 95% CI 1.33-2.09) and overall success rates (RR 1.25; 95% CI 1.08-1.44) than palpation. The approach without dynamic needle-tip positioning was not associated with higher first-attempt (RR 1.17; 95% CI 0.91-1.49) and overall success rates (RR 1.10; 95% CI 0.90-1.33) than palpation. Compared to the approach without dynamic needle-tip positioning, dynamic needle-tip positioning was associated with a higher first-attempt success rate (RR 1.43; 95% CI 1.07-1.92), but not a higher overall success rate (RR 1.14; 95% CI 0.92-1.41).

Conclusions: Dynamic needle-tip positioning is efficacious for peripheral venous catheterization in children. It would be better to include dynamic needle-tip positioning for the ultrasound-guided short-axis out-of-plane approach.


Reference:

Takeshita J, Nakayama Y, Tachibana K, Nakajima Y, Shime N. Ultrasound-Guided Short-Axis Out-of-Plane Approach With or Without Dynamic Needle-Tip Positioning for Peripheral Venous Catheterization in Pediatric Patients: A Systematic Review With Network Meta-Analysis. J Cardiothorac Vasc Anesth. 2023 May 5:S1053-0770(23)00273-2. doi: 10.1053/j.jvca.2023.04.039. Epub ahead of print. PMID: 37217420.