“This study evaluates the capacity of ultrasonography as a diagnostic method to confirm the proper positioning of central venous catheter (CVC) when compared to the current gold standard, chest radiography (CR)” Oliveira et al (2020).

Abstract:

PURPOSE: This study evaluates the capacity of ultrasonography as a diagnostic method to confirm the proper positioning of central venous catheter (CVC) when compared to the current gold standard, chest radiography (CR).

METHODS: A prospective study was performed including children from 0 to 14 incomplete years, who underwent CVC placement between March and May 2018 at a teaching hospital in Brazil. A four-chamber view of the heart was performed with ultrasound during a rapid injection of saline solution to identify hyperechoic images and confirm the central position of the catheter. After that, a CR was performed. The diagnostic quality of ultrasound was evaluated based on accuracy, sensitivity, specificity, positive and negative predictive values.

RESULTS: A total of 21 patients were analyzed. The mean age was 3.95 ± 4.01 years. The preferred puncture site was the right internal jugular vein (71.4%). Ultrasound accuracy to detect CVC positioning was 81%. Sensitivity, specificity and positive and negative predictive values were 33%, 100%, 100% and 79%, respectively.

CONCLUSION: Ultrasound is a reliable method for detection of CVC positioning. Even so, with the four-chamber cardiac view, this method is unable to identify catheters inside heart chambers, therefore, needing to confirm the positioning with CR.

Reference:

Oliveira, L., Pilz, L., Tognolo, C.M., Bischoff, C., Becker, K.A., Oliveira, G.G., Neves, P.J.F., Fachin, C.G., Agulham, M.A. and Dias, A.I.B.S. (2020) Comparison between ultrasonography and X-ray as evaluation methods of central venous catheter positioning and their complications in pediatrics. Pediatric Surgery International. March 30th. doi: 10.1007/s00383-020-04642-y. (Epub ahead of print).