Accidental removal of medical devices

“The nasoenteral catheter was the most frequently removed device (44.4%), followed by the central venous catheter (11.4%), the indwelling bladder catheter (9.0%), and the peripheral venous catheter (6.9%)” Oliveira et al (2025).

Read More »

Catheter-related infection risk factors

“For uncuffed, non-tunneled dual-lumen catheters used for dialysis vascular access, the jugular insertion site does not demonstrate a reduced risk of CRBSI compared to the femoral site. However, jugular catheter placement is associated with a longer dwelling time and a lower mortality rate.” Phatpituk et al (2025).

Read More »

Needle-free connector evaluation

“This study examined the performance of various NFC technologies with PICC and Midline. While no device eliminates BV, positive displacement NFCs showed lower flow reflux compared to the others when used with PICC. No difference between clamping sequences was observed for neutral and anti-reflux NFCs” Privitera et al (2025).

Read More »

Peripheral intravenous cannula removal in children

“To determine the effects of using an alcohol-free, silicone-based adhesive remover spray and squeezing a stress ball on pain and fear of pain during the removal of peripheral intravenous cannulas and fixation materials (acrylate-based hypoallergenic adhesives) in children aged 6-9 years” Guzel Polat et al (2025).

Read More »

Blood culture diagnostic stewardship model – Full Text

“The medical community recently experienced a severe shortage of blood culture media bottles. Rates of blood stream infection (BSI) among critically ill children are low. We sought to design a machine learning (ML) model able to identify children at low risk for BSI to improve blood culture diagnostic stewardship” Martin et al (2025).

Read More »

Intravenous smart pump review

“The first programmable infusion pumps were invented over 50 years ago, but their adoption in hospitals was slow, and their initial functions were limited to basic programming in milliliters per hour” Blake et al (2025).

Read More »

Safety-engineered port access needles – Full Text

“We have shown significant differences regarding product characteristics of safety mechanisms of port access needles. Our evaluation approach provides specific data for both, technical (e.g., single-handed activation) and personal device selection criteria (e.g., preference of the safety mechanism)” Gabler et al (2025).

Read More »

Vascular Access and IV Therapy Resource

"IVTEAM is a global vascular access and infusion therapy resource that provides daily updates for clinical teams. Our updates ensure health care professionals can easily keep up to date with the most relevant evidence related to vascular access and infusion therapy."
IVTEAM
IVTEAM

Accidental removal of medical devices

“The nasoenteral catheter was the most frequently removed device (44.4%), followed by the central venous catheter (11.4%), the indwelling bladder catheter (9.0%), and the peripheral venous catheter (6.9%)” Oliveira et al (2025).

Read More »

Catheter-related infection risk factors

“For uncuffed, non-tunneled dual-lumen catheters used for dialysis vascular access, the jugular insertion site does not demonstrate a reduced risk of CRBSI compared to the femoral site. However, jugular catheter placement is associated with a longer dwelling time and a lower mortality rate.” Phatpituk et al (2025).

Read More »

Needle-free connector evaluation

“This study examined the performance of various NFC technologies with PICC and Midline. While no device eliminates BV, positive displacement NFCs showed lower flow reflux compared to the others when used with PICC. No difference between clamping sequences was observed for neutral and anti-reflux NFCs” Privitera et al (2025).

Read More »

Peripheral intravenous cannula removal in children

“To determine the effects of using an alcohol-free, silicone-based adhesive remover spray and squeezing a stress ball on pain and fear of pain during the removal of peripheral intravenous cannulas and fixation materials (acrylate-based hypoallergenic adhesives) in children aged 6-9 years” Guzel Polat et al (2025).

Read More »

Blood culture diagnostic stewardship model – Full Text

“The medical community recently experienced a severe shortage of blood culture media bottles. Rates of blood stream infection (BSI) among critically ill children are low. We sought to design a machine learning (ML) model able to identify children at low risk for BSI to improve blood culture diagnostic stewardship” Martin et al (2025).

Read More »

Intravenous smart pump review

“The first programmable infusion pumps were invented over 50 years ago, but their adoption in hospitals was slow, and their initial functions were limited to basic programming in milliliters per hour” Blake et al (2025).

Read More »

Safety-engineered port access needles – Full Text

“We have shown significant differences regarding product characteristics of safety mechanisms of port access needles. Our evaluation approach provides specific data for both, technical (e.g., single-handed activation) and personal device selection criteria (e.g., preference of the safety mechanism)” Gabler et al (2025).