How to take uncontaminated blood samples from central venous catheters

0

This study demonstrates the feasibility of replacing the discard blood sampling method for central vascular access devices with the push-pull method” Byrne (2016).

Abstract:

This study demonstrates the feasibility of replacing the discard blood sampling method for central vascular access devices with the push-pull method. A comparative, within-subject design was used to evaluate 61 unique, paired blood samples from 1 adult outpatient oncology clinic. A 21-measure laboratory panel was conducted on each of the paired samples. Interpretation showed a small mean bias and excellent agreement between the methods. Blood samples obtained using the push-pull method were within clinically acceptable ranges. No hemolysis was noted by laboratory evaluation of 59 samples.

Reference:

Byrne, D. (2016) Comparing the Push-Pull Versus Discard Blood Sample Method From Adult Central Vascular Access Devices. Journal of Infusion Nursing. 39(3), p.130–135.

doi: 10.1097/NAN.0000000000000167