Esophageal perforation during cuffed tunneled catheter insertion

0

In this report, we present a case that was misplaced the catheter in esophagus and to analyze the reason of catheter malposition during percutaneous tunneled hemodialysis catheter insertion” Burak Çildağ and Faruk Kutsi Köseoğlu (2016).

Abstract:

The percutaneous catheterization of central veins is increasingly used in nephrological practice as a temporary or permanent vascular access. Some mechanical complications may occur during insertion of catheter such as misplaced catheter. In this report, we present a case that was misplaced the catheter in esophagus and to analyze the reason of catheter malposition during percutaneous tunneled hemodialysis catheter insertion.

Reference:

Burak Çildağ, M. and Faruk Kutsi Köseoğlu, Ö. (2016) Esophageal perforation during cuffed tunneled catheter introduction: First case in literature. Hemodialysis International. April 7th. [Epub ahead of print].

doi: 10.1111/hdi.12416.