Search
"The use of ultrasound guidance resulted in an almost three-fold increase in odds for the first-attempt success rate in patients with predicted DIVA compared with the traditional technique of PIVC" Poulsen et al (2023).

Impact of ultrasound guidance on first-attempt peripheral IV cannulation success

Abstract:

Identifying patients at risk of difficult intravenous access (DIVA) and increasing the success rates of peripheral intravenous catheterization (PIVC), preferably on the first catheterization attempt, is of clinical importance. The aim of this study was to compare the use of dynamic ultrasound guidance for PIVC with the traditional technique of visualization and palpation in patients with predicted DIVA. A systematic review and meta-analysis comparing ultrasound-guided PIVC with the traditional technique was performed. Data were systematically collected through MEDLINE and EMBASE databases from inception to March 2021. Eligibility criteria included randomized controlled trials performed on patients meeting criteria for difficult catheterization comprising either (a) no palpable or visible veins, (b) previous history of difficult venous catheterization, (c) patient age less than 4 years, (d) suspicion of difficult catheterization by operator, or (e) two or more unsuccessful attempts using the traditional technique before enrollment were included. For all outcomes, a random-effects meta-analysis using the DerSimonian and Laird method was performed. The primary outcome was the first-attempt success rate, and the secondary outcomes were the overall success rate and the number of attempts for successful intravenous catheterization. Bias was assessed using the Revised Cochrane Risk of Bias tool. Seven studies with a total of 994 patients were included. Patients comprised both children and adults and settings included operating rooms, emergency departments, and intensive care units. Ultrasound guidance was associated with a higher first-attempt success rate (OR, 3.07; 95% CI, 1.66-5.65; P < 0.001). For the secondary outcomes, ultrasound guidance was associated with a higher overall success rate (OR, 3.02; 95% CI, 1.04-8.79; P = 0.04); however, this finding did not meet statistical significance in a sensitivity analysis (OR, 2.90; 95% CI, 0.71-11.93; P = 0.14). Ultrasound was not associated with a significantly different number of attempts compared with the traditional technique (difference in means, 0.14; 95% CI, -0.32 to 0.05; P = 0.15). The use of ultrasound guidance resulted in an almost three-fold increase in odds for the first-attempt success rate in patients with predicted DIVA compared with the traditional technique of PIVC.


Reference:

Poulsen E, Aagaard R, Bisgaard J, Sørensen HT, Juhl-Olsen P. The effects of ultrasound guidance on first-attempt success for difficult peripheral intravenous catheterization: a systematic review and meta-analysis. Eur J Emerg Med. 2023 Jan 20. doi: 10.1097/MEJ.0000000000000993. Epub ahead of print. PMID: 36727865.