Search
"We report a neonate who developed external iliac artery thrombosis after insertion of femoral venous catheter, without an apparent arterial puncture during the procedure" Amiti et al (2021).

Femoral catheterisation complications in neonate

Abstract:

We report a neonate who developed external iliac artery thrombosis after insertion of femoral venous catheter, without an apparent arterial puncture during the procedure. The baby developed acute limb ischaemia. As there was no improvement despite heparin infusion for 24 hours, thrombectomy was done. Following surgery, the limb perfusion improved gradually in 1 week. However, pulses did not reappear even after antithrombotic therapy for 3 months. There was residual Doppler abnormality in the form of severe narrowing at the origin of superficial femoral artery with reduced flow velocity in superficial femoral, popliteal and tibial arteries. The baby was kept under regular follow-up, with a plan for clinical assessment and Doppler every 6 months and to perform a vascular reconstructive surgery if he develops any clinical feature of chronic limb ischaemia. The baby is now 1 year of age. He is walking normally and there is no limb length discrepancy.

Reference:

Amiti A, Abiramalatha T, Ayyappan MK, Rajendran UD. External iliac artery thrombosis: an unusual complication of femoral venous catheterisation in a neonate. BMJ Case Rep. 2021 Apr 23;14(4):e240099. doi: 10.1136/bcr-2020-240099. PMID: 33893124.