Search

The aim of the study was to evaluate the incidence of peripheral inserted central catheter (PICC) tip malposition when the catheter is inserted under real-time ultrasound (RTUS) guidance when compared with conventional landmark (CL) technique in neonates” Oleti et al (2018).

Abstract:

OBJECTIVE: The aim of the study was to evaluate the incidence of peripheral inserted central catheter (PICC) tip malposition when the catheter is inserted under real-time ultrasound (RTUS) guidance when compared with conventional landmark (CL) technique in neonates. Additional objectives were to evaluate the PICC longevity and central line associated blood stream infections (CLABSI).

STUDY DESIGN: In this randomised controlled trial, neonates were randomised to ‘RTUS’ (n = 40) or ‘CL’ (n = 40) groups. PICC tip was placed under ultrasound guidance in lower third of superior vena cava in the RTUS group. In ‘CL’ group, PICC was inserted as calculated by anatomical landmarks.

RESULTS: The birth weight (1286 (926, 1662) vs. 1061 (889, 1636) g) and gestation (31.12 (3.1) vs. 31.4 (3.6) wks) were comparable among the groups. RTUS guidance during PICC insertion reduced incidence of tip malposition by 52% (67.5 vs. 32.5%; RR: 0.48; 95% CI: 0.29-0.79). The longevity of PICC and episodes of CLABSI were however similar in the two groups.

CONCLUSIONS: Real-time ultrasound guidance during PICC placement reduces the incidence of tip malposition.

You may also be interested in…

[rp4wp]



Reference:

Oleti, T., Jeeva Sankar, M., Thukral, A., Sreenivas, V., Gupta, A.K., Agarwal, R., Deorari, A.K. and Paul, V.K. (2018) Does ultrasound guidance for peripherally inserted central catheter (PICC) insertion reduce the incidence of tip malposition? – a randomized trial. Journal of Perinatology. October 22nd. [epub ahead of print].

doi: 10.1038/s41372-018-0249-x.