Search

This case differs that the catheter itself through the sheath introducer can cause venous injury that may lead to the malposition of CVC particularly through an approach to the left internal jugular vein” Lim et al (2017).

Abstract:

RATIONALE: The misplacement of central venous catheter (CVC) can occur more often at the left jugular vein than the right side due to anatomic differences. And many of the previously reported cases are about catheter misplacement resulting from vessel penetration associated with guidewire. This case differs that the catheter itself through the sheath introducer can cause venous injury that may lead to the malposition of CVC particularly through an approach to the left internal jugular vein.

[ctt link=”5hHU1″ template=”1″]ReTweet if useful… Case study describes malposition of a central venous catheter https://ctt.ec/5hHU1+ @ivteam #ivteam[/ctt]

PATIENT CONCERNS, DIAGNOSIS, INTERVENTIONS, AND OUTCOMES: We cannulated a large-bore CVC with a sheath introducer, namely mult-lumen access catheter (MAC) in the left jugular vein of patient under anesthesia using ultrasound and inserted the additional central venous oximetry catheter through the sheath introducer of MAC and confirmed aspiration of blood. However, the postoperative imaging study revealed malposition of the tip of the oximetry catheter in the mediastinum.

MAIN LESSON: The insertion of additional catheter through the sheath introducer needs to be carried out as carefully as the insertion of guidewire and should be confirmed with imaging study after the procedure.

Reference:

Lim, J.A., Jee, C.H. and Kwak, K.H. (2017) The malposition of a central venous catheter through a sheath introducer via the left internal jugular vein: A case report. Medicine. 96(24), p.e7187.

doi: 10.1097/MD.0000000000007187.

Thank you to our partners for supporting IVTEAM
[slideshow_deploy id=’23788’]