Ultrasonographically guided peripheral intravenous cannulation

ultrasoundprobe

Intravenous literature: Stein, J., George, B., River, G., Hebig, A. and McDermott, D. (2009) Ultrasonographically guided peripheral intravenous cannulation in emergency department patients with difficult intravenous access: a randomized trial. Annals of Emergency Medicine. 54(1), p.33-40.

Abstract:

STUDY OBJECTIVE: We seek to compare ultrasonographically guided peripheral intravenous access to a non-ultrasonographically guided method in a randomized trial of emergency department patients with difficult intravenous access.

METHODS: A prospective cohort of patients with difficult intravenous access was established. Patients were randomized to 2 groups: (1) intravenous access obtained through an ultrasonographically guided technique or (2) intravenous access obtained through non-ultrasonographically guided methods. Outcomes measured were number of attempts after enrollment, time to cannulation from enrollment, and patient satisfaction. Groups were compared with nonparametric analysis.

RESULTS: Fifty-nine patients were randomized. Twenty-eight patients were randomized to the ultrasonography group and 31 to the no ultrasonography group. A median of 2 further intravenous attempts was required in each group before successful cannulation, corresponding to a difference of 0 attempts (95% confidence interval [CI] 0 to 1 attempts). Time to cannulation showed a median of 39 minutes in the ultrasonography group compared with 26 minutes for the no ultrasonography group, giving a median increase of 13 minutes for the ultrasonographically guided group (95% CI -5 to 28 minutes). Patients in the ultrasonography group had a median Likert satisfaction score of 8 compared with 7 for the no ultrasonography group, giving a median increase of 1 on this scale in the ultrasonography group (95% CI 0 to 2).

CONCLUSION: Ultrasonographically guided peripheral intravenous cannulation did not decrease the number of attempts or the time to successful catheterization, nor did it improve patient satisfaction compared with the group that did not use ultrasonography. Superiority of ultrasonographically guided peripheral intravenous cannulation is not supported by this study.


Other stories

Add IVTEAM to Technorati Favorites del.icio.us:Ultrasonographically guided peripheral intravenous cannulation digg:Ultrasonographically guided peripheral intravenous cannulation spurl:Ultrasonographically guided peripheral intravenous cannulation wists:Ultrasonographically guided peripheral intravenous cannulation simpy:Ultrasonographically guided peripheral intravenous cannulation newsvine:Ultrasonographically guided peripheral intravenous cannulation blinklist:Ultrasonographically guided peripheral intravenous cannulation furl:Ultrasonographically guided peripheral intravenous cannulation reddit:Ultrasonographically guided peripheral intravenous cannulation fark:Ultrasonographically guided peripheral intravenous cannulation blogmarks:Ultrasonographically guided peripheral intravenous cannulation Y!:Ultrasonographically guided peripheral intravenous cannulation smarking:Ultrasonographically guided peripheral intravenous cannulation magnolia:Ultrasonographically guided peripheral intravenous cannulation segnalo:Ultrasonographically guided peripheral intravenous cannulation gifttagging:Ultrasonographically guided peripheral intravenous cannulation

Comments

Please leave a comment?