We present a case report where USG was used for detection of a misplaced CVC (from right internal jugular vein to right subclavian vein). With ultrasound, the location of the catheter tip can be confirmed in very less time compared with chest X-ray” Kumar et al (2017).

Abstract:

Central venous catheter (CVC) insertion is associated with many potential complications; malposition of the catheter is one of them. A chest X-ray is routinely done to detect the malposition of catheter, but sometimes it has been seen that X-ray is time-consuming and its accuracy is also low for determining the exact position of the catheter tip. In our case, an ultrasonography (USG)-guided CVC was placed into the right internal jugular vein of the patient.

[ctt link=”DAe9s” template=”1″]ReTweet if useful… Malposition of central venous catheter detected by ultrasonography-guided saline flush https://ctt.ec/DAe9s+ @ivteam #ivteam[/ctt]

As there was no ECG change obtained during insertion of guidewire and catheter, malposition was suspected, which was easily detected by a novel USG-guided saline flush test. We present a case report where USG was used for detection of a misplaced CVC (from right internal jugular vein to right subclavian vein). With ultrasound, the location of the catheter tip can be confirmed in very less time compared with chest X-ray.

Reference:

Kumar, N., Kaushal, A., Dev Soni, K. and Tomar, G.S. (2017) A rare case of malposition of central venous catheter detected by ultrasonography-guided saline flush test. BMJ Case Reports. July 6th.

doi: 10.1136/bcr-2017-220657.